AMPMS0=0, AMPMS7=0
Operational Amplifier 1 Minus Input Select Register
AMPMS0 | AMP1- pin select 0 (0): AMP1- pin is not connected to the AMP1 minus input 1 (1): AMP1- pin is connected to the AMP1 minus input |
Reserved | These bits are read as 000000. The write value should be 000000. |
AMPMS7 | OPAMP1 output select 0 (0): OPAMP1 output is not connected to the AMP1 minus input 1 (1): OPAMP1 output is connected to the AMP1 minus input |